Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Braz. dent. j ; 29(6): 562-568, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-974193

ABSTRACT

Abstract This study aimed to evaluate the effects of the Herbst appliance on the proclination and protrusion of the lower incisors, and to verify if the device causes alveolar bone loss in the anterior region of the mandible. This is a retrospective study. The sample consisted of 35 individuals. The treatment group consisted of 22 individuals (8 girls and 14 boys; initial mean age of 8.2 years) who used the Cantilever Herbst appliance for a period of 12 months. The control group consisted of 13 individuals (3 girls and 10 boys; initial mean age of 8.9 years) who received no treatment and were followed up for a period of approximately 18 months. Cone-beam computed tomography scans were performed at the beginning and at the end of the observational period. The medullary bone thickness (MT), buccal cortical bone thickness (BCT), lingual cortical bone thickness (LCT), and lower incisors proclination and protrusion were evaluated. Data were submitted to statistical analysis (ANCOVA and Student's t-test) with a significance level of 5%. There was no significant difference in MT, BCT, LCT and incisor proclination between groups. Incisor proclination increased in the treated group with no statistical significance. The treatment group showed a significant increase in the protrusion of the incisors (p = 0.02). The Herbst appliance promoted a small proclination and protrusion of the lower incisors, without relevant clinical implications. The Herbst appliance did not cause bone loss in the anterior region of the mandible during Class II treatment.


Resumo O objetivo deste estudo foi avaliar os efeitos do aparelho de Herbst na proclinação e protrusão dos incisivos inferiores, bem como verificar se o aparelho causa perda óssea alveolar na região anterior da mandíbula. Trata-se de um estudo retrospectivo. Foi utilizada uma amostra de 35 indivíduos. O grupo tratado foi formado por 22 indivíduos (8 meninas e 14 meninos; idade média inicial de 8,2 anos) que utilizaram o aparelho de Herbst com Cantilever por um período de 12 meses. O grupo controle foi composto por 13 indivíduos (3 meninas e 10 meninos; idade média inicial de 8,9 anos) que não receberam tratamento e foram acompanhados por um período de aproximadamente 18 meses. Exames de tomografia computadorizada de feixe cônico foram realizados no início e no final do período observacional. Foram avaliadas a espessura óssea medular (EM), espessura óssea cortical vestibular (ECV), espessura óssea cortical lingual (ECL), proclinação e protrusão dos incisivos inferiores. Os dados foram submetidos a análise estatística (ANCOVA e teste t de Student) com nível de significância de 5%. Não houve alteração estatisticamente significativa na EM, ECV, ECL e proclinação dos incisivos entre os grupos. Houve um aumento na proclinação dos incisivos no grupo tratado, sem significância estatística. O grupo tratado apresentou aumento significativo na protrusão dos incisivos (p=0,02). O aparelho de Herbst promoveu uma pequena proclinação e protrusão dos incisivos inferiores, sem implicações clínicas relevantes. O aparelho de Herbst não causou perda óssea na região anterior da mandíbula durante o tratamento da Classe II.


Subject(s)
Humans , Male , Female , Child , Orthodontic Appliances, Functional , Cone-Beam Computed Tomography/methods , Incisor/diagnostic imaging , Retrospective Studies , Treatment Outcome , Mandible/diagnostic imaging
2.
Dental press j. orthod. (Impr.) ; 23(2): 87-109, Mar.-Apr. 2018. graf
Article in English | LILACS | ID: biblio-953019

ABSTRACT

ABSTRACT Introduction: Considering the large number of fixed functional appliances, choosing the best device for your patient is not an easy task. Objective: To describe the development of fixed functional appliances as well as our 20-year experience working with them. Methods: Fixed functional appliances are grouped into flexible, rigid and hybrid. They are different appliances, whose action is described here. Four clinical cases will be reported with a view to illustrating the different appliances. Conclusions: Rigid fixed functional appliances provide better skeletal results than flexible and hybrid ones. Flexible and hybrid appliances have similar effects to those produced by Class II elastics. They ultimately correct Class II with dentoalveolar changes. From a biomechanical standpoint, fixed functional appliances are more recommended to treat Class II in dolichofacial patients, in comparison to Class II elastics.


RESUMO Introdução: considerando-se o grande número de aparelhos propulsores mandibulares, não é uma tarefa fácil escolher o melhor deles para o seu paciente. Objetivo: descrever o desenvolvimento desses aparelhos e a experiência clínica de vinte anos dos autores na sua utilização. Métodos: os aparelhos funcionais fixos aqui apresentados foram classificados em flexíveis, rígidos e híbridos, e o modo de ação de cada um deles foi descrito e ilustrado por meio de quatro casos clínicos. Conclusões: os aparelhos propulsores rígidos fornecem mais resultados esqueléticos do que os flexíveis e os híbridos. Esses últimos têm efeito semelhante ao uso de elásticos com direção de Classe II e, basicamente, corrigem a má oclusão de Classe II com alterações dentoalveolares. Do ponto de vista biomecânico, os propulsores fixos estão mais indicados para tratar a Classe II em pacientes dolicofaciais do que os elásticos de Classe II.


Subject(s)
Humans , Male , Female , Child , Adolescent , Outcome and Process Assessment, Health Care , Tooth Movement Techniques/instrumentation , Orthodontic Appliances, Fixed , Malocclusion, Angle Class II/therapy , Orthodontic Appliances , Orthodontic Appliances, Removable , Orthodontic Wires , Tooth Movement Techniques/methods , Tomography, X-Ray Computed , Cephalometry , Treatment Outcome , Orthodontic Brackets , Orthodontic Appliance Design , Orthodontic Appliances, Functional , Photography, Dental , Malocclusion, Angle Class II/diagnostic imaging
3.
Ortho Sci., Orthod. sci. pract ; 10(40): 42-46, 2018. graf, tab
Article in Portuguese | LILACS, BBO | ID: biblio-879725

ABSTRACT

O objetivo deste estudo foi comparar diferentes métodos de remoção do remanescente adesivo após a descolagem de bráquetes em relação à rugosidade superficial do esmalte. Trinta pré-molares com superfície lingual íntegra e sem fraturas foram selecionados. Os dentes foram submetidos à profilaxia com pasta de pedra-pomes e água e fixados individualmente com auxílio de uma morsa à bancada de trabalho. A rugosidade superficial de cada espécime foi medida com auxílio de um rugosímetro. Foram efetuadas três leituras em posições diferentes e a média das leituras foi utilizada. Após a leitura inicial os bráquetes foram colados utilizando a resina Transbond XT, de acordo com as instruções do fabricante. Os espécimes foram armazenados em estufa a 37ºC e 100% de umidade por 24hs. Depois os bráquetes foram removidos e os espécimes foram aleatoriamente distribuídos em 3 grupos (n=10) de acordo com o sistema utilizado para remoção do remanescente adesivo: broca multilaminada 12 lâminas (Jet), pontas de óxido de alumínio (DHPRO) e pontas de fibra de vidro (Fiberglass). Uma segunda leitura de rugosidade foi realizada, seguindo os mesmos parâmetros descritos. Em seguida, os espécimes foram submetidos ao polimento com pasta de pedra-pomes e água e uma terceira leitura foi realizada. Os dados foram submetidos à análise estatística (ANOVA p<0,05). Não houve diferença estatística significativa nos valores de rugosidade superficial entre os grupos (p>0,05), independentemente do momento de avaliação. Conclui-se que os métodos avaliados não interferiram na rugosidade superficial do esmalte, sendo seguros para utilização na remoção do remanescente adesivo. (AU)


The objective of this study was to compare different methods of remaining adhesive removal after bracket debonding in relation to enamel surface roughness. Thirty premolars with intact lingual surface without fractures were selected. The teeth were submitted to prophylaxis with pumice paste and water and then set individually with the aid of a vise to the workbench. Surface roughness of each specimen was measured by a roughness meter. Three readings were performed in different positions and readings average was used as the roughness value for each specimen. After the initial reading brackets were bonded using the Transbond XT resin, according to the manufacturer's instructions. The specimens were stored at 37°C and 100% humidity for 24 hours. After the brackets were removed, the specimens were randomly divided into 3 groups (n=10) according to the system used to remove the remaining adhesive (laminated drill ­ Jet, aluminum oxide tips ­ DHPRO and fiberglass tips ­ Fiberglass). A second roughness reading was performed following the same parameters described. Then the specimens were polished with pumice paste and water and a third reading was performed. Data was subjected to statistical analysis (ANOVA p<0.05). No statistically significant differences in surface roughness values was found among the groups (p>0.05), regardless of evaluation time. It can be concluded that the methods evaluated did not affect the enamel surface roughness and are safe for use when removing the remaining adhesive.(AU)


Subject(s)
Braces , Dental Enamel , Orthodontics
4.
Ortho Sci., Orthod. sci. pract ; 10(38): 23-33, 2017. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-837355

ABSTRACT

Objective: To evaluate the shear bond strength of passive self-ligating brackets (Tellus EX, Eurodonto) fixed to enamel using different materials and adhesive protocols. Materials and methods: Forty-eight bovine incisors were selected and divided into 6 groups according to the material and the adhesive protocol, as follows: G1 - Orthodontic resin Transbond XT, 3M Unitek (TB) associated to Single Bond 2 adhesive, 3M ESPE (SB2), G2 - TB associated with Ambar adhesive, FGM (AB), G3 - TB without application of adhesive, G4 - Orthodontic resin Orthocem, FGM (OC) associated with SB2, G5 - OC associated with AB and G6 - OC without adhesive application. The brackets were fixed following the manufacturers' instructions and stored in deionized water at 37°C for 24h. After that, the specimens were subjected to shear bond strength test (SBS) in a universal test machine (DL2000, Emic) with a crosshead speed of 0.5 mm/min and evaluated for adhesive remnant index (ARI). The data were submitted to ANOVA two criteria and Tukey's test (α = 0.05). Results: There was statistically significant difference between groups (p<0.05). The combination TB/SB2 (G1) showed significantly higher SBS values than TB/without adhesive (G3) and OC/SB2 (G4), not differing from the other groups. The lowest SBS values were observed for the TB group/without adhesive (G3), which did not differ from OC/SB2 groups (G4) and OC/without adhesive (G6). Conclusion: The use of adhesives before application of orthodontic resin promotes improvement in SBS values, except for the OC material, which can be used without adhesive association, without a significant adhesion reduction.(AU)


Objetivo: Avaliar a resistência de união ao cisalhamento de bráquetes autoligados passivos (Tellus EX, Eurodonto), fixados com diferentes materiais e protocolos adesivos. Material e metódos: Quarenta e oito incisivos bovinos foram selecionados e distribuídos em 6 grupos de acordo com o material e o protocolo adesivo, sendo: G1 - resina ortodôntica Transbond XT, 3M Unitek (TB) associada ao adesivo Single Bond 2, 3M ESPE (SB2), G2 - TB associado ao adesivo Ambar, FGM (AB), G3 - TB sem aplicação de adesivo, G4 - resina ortodôntica Orthocem, FGM (OC) associada a SB2, G5 - OC associado a AB e G6 - OC sem aplicação de adesivo. Os bráquetes foram fixados seguindo as instruções dos fabricantes e armazenados em água deionizada a 37ºC por 24h. Depois, os espécimes foram submetidos ao ensaio de resistência de união cisalhamento (RU) em máquina de ensaio universal (DL2000, Emic) à velocidade de 0,5 mm/min e avaliados quanto ao índice de remanescente adesivo (IRA). Os dados foram submetidos à análise de variância dois critérios e teste de Tukey (α=0,05). Resultados: Houve diferença estatística significativa entre os grupos (p<0,05). A combinação TB/SB2 (G1) apresentou significativamente maiores valores de RU do que TB/sem adesivo (G3) e OC/SB2 (G4), não diferindo dos demais grupos. Os menores valores RU foram observados para o grupo TB/sem adesivo (G3), o qual não diferiu dos grupos OC/SB2 (G4) e OC/sem adesivo (G6). Conclusão: O uso de adesivos antes da aplicação da resina ortodôntica promove melhora nos valores de RU, exceto para o material OC, o qual pode ser utilizado sem associação a adesivo, sem que haja redução significativa da adesão.(AU)


Subject(s)
Animals , Cattle , Orthodontic Brackets , Resin Cements , Shear Strength
5.
Ortho Sci., Orthod. sci. pract ; 10(39): 104-130, 2017. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-868261

ABSTRACT

A Ortodontia está passando por uma nova fase. Muitos pacientes adultos estão buscando o tratamento atualmente e não querem usar um aparelho convencional. Isso tem feito com que a Ortodontia desenvolva novos métodos de tratamento mais estéticos e também aprimore os já existentes. Duas modalidades de tratamento têm ganhado muito destaque nos últimos anos: a Ortodontia Lingual e os Alinhadores Removíveis. O objetivo deste artigo é descrever a técnica lingual Harmony e os alinhadores removíveis Essix e Clear Aligner, comparando-os e mostrando o tratamento de dois casos clínicos. Para o caso tratado com a técnica Lingual foi escolhido o aparelho Harmony devido à necessidade de grande controle de torque nos incisivos superiores. O caso tratado com alinhadores era um caso simples de recidiva pós-tratamento ortodôntico. Os casos clínicos descritos evidenciaram o papel importante que as novas modalidades de tratamento estético podem ter na Ortodontia contemporânea. Cabe ao ortodontista clínico conhecer essas ferramentas e as utilizar nos casos apropriados.(AU)


Orthodontics is going through a new phase. Many adult patients are currently seeking treatment and do not want to use a conventional device. This has led Orthodontics to develop new aesthetic treatment methods, as well as to improve existing ones. Two treatment modalities have gained much prominence in recent years: Lingual Orthodontics and Removable Aligners. The purpose of this article isx to describe the Harmony lingual technique and the Essix and Clear Aligner removable aligners, comparing them and showing the treatment of two clinical cases. For the case treated with the lingual technique, the Harmony device was chosen due to the need for great torque control in the upper incisors. The case treated with aligners was a simple case of orthodontic posttreatment relapse. The clinical cases described evidenced the important role that the new modalities of aesthetic treatment can have in contemporary Orthodontics. It is up to the clinical orthodontist to know these tools and use them in appropriate clinical cases.(AU)


Subject(s)
Humans , Male , Female , Adult , Esthetics, Dental , Orthodontics
6.
Braz. dent. j ; 27(5): 537-542, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828028

ABSTRACT

Abstract The aim of this study was to evaluate the effect of enamel and dentin surface treatment on the micro-shear bond strength of self-adhesive cement. Seventy-two extracted third molars had their crowns embedded in acrylic resin and worn to obtain a flat enamel or dentin surface. The enamel and dentin specimens were randomly assigned to 8 groups (n=12) that were based on surface treatment (11.5% polyacrylic acid solution or no treatment), substrate condition (wet or dry) and storage period (1 day or 90 days), and treated accordingly. Cylinders (1 × 1 mm) were fabricated using self-adhesive resin cement (RelyX U200) following the manufacturer's instructions. The specimens were stored in distilled water at 37 °C for either 1 day or 90 days and subjected to micro-shear bond strength test (EMIC DL 2000 at 0.5 mm/min). After this, the failure type of the specimens was determined. Data were subjected to statistical analysis (a=0.05). According to the results, the 11.5% polyacrylic acid application decreased the bond strength in both enamel and dentin samples. The moist groups showed higher bond strength than the dry ones, regardless of the substrate and surface treatment. Storage period did not influence bond strength. In conclusion, surface treatment with 11.5% polyacrylic acid and absence of moisture decreased the bond strength of the resin-cement (RelyU200), regardless of the storage period.


Resumo O objetivo do estudo foi avaliar o efeito de tratamentos de superfície em esmalte e dentina na resistência de união (RU) de um cimento auto-adesivo. As coroas de setenta e dois terceiros-molares foram incluídas em resina acrílica e desgastadas para obtenção de áreas planas em esmalte e dentina. Os espécimes de esmalte e dentina foram aleatoriamente distribuídos em 8 grupos (n=12) de acordo com: tratamento de superfície (sem tratamento ou aplicação de solução de ácido poliacrílico a 11,5%), condição do substrato (seco ou úmido) e período de armazenamento (1 dia ou 90 dias). Após, cilindros (1 x 1 mm) foram confeccionados na superfície dos espécimes utilizando cimento resinoso auto-adesivo (Rely X U200) segundo as instruções do fabricante. Os espécimes foram armazenados em água destilada a 37 oC por 1 dia ou 90 dias e submetidos ao ensaio mecânico de microcisalhamento (EMIC DL 2000 a 0,5 mm/min). O tipo de falha de cada espécime foi determinado após ensaio. Os dados foram submetidos à análise estatística (a=0,05). De acordo com os resultados, a aplicação de ácido poliacrílico a 11,5% diminuiu a RU em ambos substratos, esmalte e dentina. Os grupos mantidos úmidos mostraram maiores valores de RU do que os secos, independentemente do substrato ou tratamento de superfície. O período de armazenamento não influenciou nos valores de RU. Concluiu-se que o tratamento de superfície com ácido poliacrílico a 11,5% e a ausência de umidade no substrato diminuíram os valores de RU para o cimento resinoso auto-adesivo, independentemente do período de armazenamento.


Subject(s)
Dental Enamel , Dentin , Resin Cements/chemistry , Surface Properties
7.
Ortho Sci., Orthod. sci. pract ; 9(36): 83-89, 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-852879

ABSTRACT

O tratamento reabilitador de agenesia de incisivos laterais superiores envolve, quase sempre, uma abordagem interdisciplinar. O presente artigo propõe-se a expor uma solução terapêutica conservadora, através de ortodontia e reabilitação protética, em um caso de agenesia congênita bilateral de incisivos laterais permanentes. A escolha da melhor opção terapêutica, o domínio da mecânica ortodôntica e a utilização da técnica reabilitadora adequada influenciaram na qualidade do resultado do tratamento.


The rehabilitation treatment of agenesis of upper lateral incisors almost always involves an interdisciplinary approach. This article aims to describe a conservative therapeutic solution through orthodontics and prosthetic rehabilitation in a case of congenital bilateral agenesis of permanent lateral incisors. The choice of the best therapeutic option, the handling of orth-odontic mechanics and the use of appropriate rehabilitative technique influenced the quality of treatment outcome.


Subject(s)
Humans , Male , Adult , Anodontia , Denture, Partial, Fixed, Resin-Bonded , Esthetics, Dental , Orthodontics
8.
Ortho Sci., Orthod. sci. pract ; 9(33): 33-38, 2016.
Article in Portuguese | LILACS | ID: lil-784595

ABSTRACT

Bráquetes cerâmicos estéticos com diferentes microestruturas podem apresentar diferenças em relação à estabilidade da interface de união e remoção. Este estudo objetivou avaliar, por meio de teste de microcisalhamento, a resistência de união entre um adesivo resinoso ortodôntico, o esmalte dentário e dois tipos de bráquetes cerâmico (monocristalino e policristalino). Inicialmente o esmalte de molares humanos foi planificado e preparado para a adesão de cilindros (0,7 mm de diâmetro e 1 mm de altura) do adesivo resinoso Transbond XT (3M, n=10). Em seguida, cilindros do mesmo adesivo foram confeccionados sobre as bases dos dois tipos de bráquetes cerâmicos (Inspire-Ormco e ClarityAdvanced-3M, n=10). Todos os espécimes foram incluídos em cilindros de PVC com resina acrílica para serem submetidos ao ensaio de resistência de união por microcisalhamento em uma máquina de ensaios universal, com velocidade de travessa de 0,5 mm/min até a fratura. Posteriormente, os espécimes foram examinados para a análise de falha. Os resultados de resistência de união foram submetidos à análise de Kruskal-Wallis (α = 0,05). Não houve diferença estatística significante entre as médias dos grupos testados (p = 0,1657). O esmalte apresentou a maior média (10,81 ± 1,85MPa), seguido do ClarityAdvanced (9,35 ± 5,30 MPa) e Inspire (7,77 ± 4,04 MPa). Todos os grupos apresentaram predominantemente a falha do tipo adesiva. Concluiu-se que os bráquetes cerâmicos, independentemente da microestrutura, apresentaram resistência de união semelhante à obtida ao esmalte dentário...


Ceramic brackets with different microstructures may exhibit differences in stability of the bond and removal interface. The aim of this study was to evaluate, via a micro-shear test, the strength of the bond between an orthodontic resin adhesive, the dental enamel, and two types of ceramic brackets (monocrystalline and polycrystalline), respectively. The human molar enamel was flattened and prepared for the 0.7 mm (diameter) ´ 1 mm (height) cylinder adhesion of the resin adhesive Transbond XT (3M, n=10). Cylinders of the same type of adhesive were subsequently built from the two types of ceramic brackets (Inspire-Ormco and ClarityAdvanced-3M, n=10). All of the specimens were then inserted in PVC cylinders with acrylic resin and subjected to bond strength assay by micro-shear in a universal testing machine; loads were applied at a crosshead speed of 0.5 mm/min until the specimens fractured. Afterwards, the specimens were examined for the presence of cracks. The bond strength results were analyzed via the Kruskal-Wallis test (α= 0.05). No statistically significant difference was found among the groups tested (p = 0.1657). In fact, the enamel ClarityAdvanced and Inspire groups had mean bond strengths of 10.81 ± 1.85 MPa, 7.77 ± 4.04 MPa, and 9.35 ± 5.30 MPa, respectively, and all three groups exhibited mainly adhesive-type fractures. It was concluded that ceramic brackets, regardless of the microstructure, exhibit similar bond strength to that of dental enamel...


Subject(s)
Humans , Dental Bonding , Orthodontic Brackets
9.
RSBO (Impr.) ; 12(1): 8-13, Jan.-Mar. 2015. ilus, tab
Article in English | LILACS | ID: lil-782780

ABSTRACT

Introduction and Objective : To evaluate the shear bond strength of brackets fixed with different materials (two light-cured nanofilled low-viscosity resins - Transbond Supreme LV and Flow Tain LV and two light-cured traditional resins - Transbond XT and Transbond Plus Color Change) after 10 min and 24 h, and to evaluate the type of failure. Material and methods : Eighty bovine incisors were selected and randomly divided into groups (n = 10) according to the material and fixation period. The brackets were bonded following the manufacturer's instructions and stored in deionized water at 37oC for 10 min or 24 h. After, the specimens were submitted to shear bond strength test at 0.5 mm/min and evaluated for adhesive remnant index (ARI). The data were submitted to Kruskal Wallis and Wilcoxon tests (p < 0.05) and the ARI scores to Chi-Square test. Results: There was a significant difference among the materials (p < 0.05) (after 10 min - Transbond XT > Transbond Plus Color Change > Transbond Supreme LV = Flow Tain LV and after 24 h - Transbond XT > Transbond Plus Color Change = Transbond Supreme LV = Flow Tain LV). There was no significant difference in resistance values between 10 min and 24 h, except for Transbond Plus Color Change. Most groups showed adhesive remaining adhered to the enamel (scores 2 and 3) without statistical significant difference (p > 0.05). Conclusion: The light-cured traditional resins showed higher resistance than the nanofilled materials. The period of fixation had no influence on the resistance for different materials, except for Transbond Plus Color Change.

10.
Braz. dent. j ; 26(1): 61-65, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-735834

ABSTRACT

The aim of this study was to evaluate the shear bond strength of rebonded ceramic brackets after subjecting the bracket base to different treatments. Seventy-five premolars were selected and randomly distributed into five groups (n=15), according to the type of the bracket surface treatment: I, no treatment, first bonding (control); II, sandblasting with aluminum oxide; III, sandblasting + silane; IV, silica coating + silane; and V, silicatization performed in a laboratory (Rocatec system). The brackets were fixed on an enamel surface with Transbond XT resin without acid etching. The brackets were then removed and their bases were subjected to different treatments. Thereafter, the brackets were fixed again to the enamel surface and the specimens were subjected to shear bond strength (SBS) test. The adhesive remnant index (ARI) was then evaluated for each specimen. Data were subjected to ANOVA and Tukey's tests (α=0.05). A statistically significant difference was observed only between Rocatec and the other groups; the Rocatec group showed the lowest SBS values. The highest SBS values were observed for group 1, without any significant difference from the values for groups II, III and IV. Most groups had a higher percentage of failures at the enamel-resin interface (score 1). It was concluded that the surface treatments of rebonded ceramic brackets were effective, with SBS values similar to that of the control group, except Rocatec group.


O objetivo do estudo foi avaliar o efeito de tratamentos da base de bráquetes cerâmicos monocristalinos na resistência de união ao esmalte após recolagem. Setenta e cinco pré-molares foram selecionados e aleatoriamente distribuídos em 5 grupos (n=15) de acordo com o tratamento da base do bráquete: I - sem tratamento, primeira colagem (controle), II - jateamento com óxido de alumínio, III - jateamento seguido da aplicação de silano, IV - jateamento com partículas de dióxido de sílica (silicatização) seguido de silano, V - silicatização realizada em laboratório (Sistema Rocatec). Os bráquetes foram colados no esmalte com Transbond XT sem condicionamento ácido. Em seguida, os bráquetes foram removidos e suas bases foram submetidas aos diferentes tratamentos. Os bráquetes foram recolados, armazenados por 24 h e submetidos ao ensaio mecânico de cisalhamento com velocidade de 0,5 mm/min. Após, o índice de remanescente adesivo (IRA) foi avaliado em cada espécime. Os dados foram submetidos à análise de variância e teste de Tukey (α=0,05). Pode-se observar que houve diferença significativa apenas entre o sistema Rocatec e os demais grupos, o qual apresentou os menores valores de resistência. Os maiores valores de resistência foram observados para o grupo I (controle), sem diferença significativa dos grupos II, III e IV. A maioria dos grupos apresentou maior porcentagem de falhas na interface esmalte/resina (escore 1). Pode-se concluir que os tratamentos da base do bráquete cerâmico foram efetivos, apresentando valores similares ao grupo controle, exceto para o grupo em que foi usado Rocatec.


Subject(s)
Humans , Male , Female , Adult , Ceramics/chemistry , Dental Bonding/methods , Orthodontic Brackets , Resin Cements/chemistry , Air Abrasion, Dental , Aluminum Oxide/chemistry , Bicuspid , Dental Debonding , Dental Stress Analysis , Light-Curing of Dental Adhesives , Shear Strength , Silanes/chemistry , Silicon Dioxide/chemistry , Surface Properties
11.
Ortodontia ; 47(6): 553-559, nov.-dez. 2014. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-760095

ABSTRACT

O objetivo deste estudo clínico prospectivo foi avaliar os deslocamentos dentoesqueléticos e a remodelação óssea em crianças tratadas com o aparelho de Herbst. A análise das alterações ocorreu através de modelos 3D, e os resultados foram comparados a um grupo-controle não tratado. Foram avaliadas 13 crianças não tratadas (idade média inicial de nove anos) e 13 tratadas com o aparelho de Herbst durante um ano (idade média inicial de 10,6 anos). Os pacientes realizaram tomografias de feixe cônico inicial (T0); após seis meses (T1, apenas para os indivíduos tratados); e no final do período de observação (T2). Modelos 3D foram construídos a partir das tomografias e sobrepostos em relação à superfície da base do crânio. Os deslocamentos das regiões anatômicas de interesse foram visualizados e quantificados (em mm) utilizando mapas coloridos tridimensionais. Os dados foram submetidos à análise estatística de Ancova (p < 0,05). Os mapas coloridos demonstraram que os incisivos superiores em pacientes tratados com o aparelho de Herbst tiveram um menor deslocamento anterior (1,44 mm; +/- 2,36) em relação ao grupo-controle, onde os incisivos superiores foram mais protruídos (3,33 mm; +/- 1,25). A remodelação na região articular foi inexpressiva, menor do que 1 mm. As variáveis da região anterior da maxila e da mandíbula foram estatisticamente insignificantes. Concluiu-se que o aparelho de Herbst não restringiu o crescimento anterior da maxila. Houve maior restrição do deslocamento dos incisivos superiores no grupo tratado do que no grupo-controle. O deslocamento da mandíbula no grupo tratado não foi maior do que no grupo-controle.


The aim of this prospective study was to evaluate the dento-skeletal displacement and bone turnover in children treated with the Herbst appliance. The analysis of the changes was through 3D models and the results were compared to an untreated control group. 13 untreated children (initial age of 9 years) and 13 treated with the Herbst appliance for 1 year (initial mean age 10.6 years) were evaluated. Patients underwent initial cone beam CT (T0), after six months (T1, only for treated individuals) and at the end of the observation period (T2). 3D models were constructed from the scans and superimposed on the surface of the skull base. The displacements of the anatomic regions of interest were visualized and quantified (in mm) using three-dimensional color maps. The data were submitted to statistical analysis Ancova (p < 0.05). The color maps showed that the upper incisors in patients treated with the Herbst appliance had a smaller anterior displacement (1.44 mm; +/- 2.36) than in the control group, where the upper incisors were more protruded (3.33 mm; +/- 1.25). Remodeling the joint region was negligible, less than 1 mm. The variables of the anterior maxilla and mandible were statistically insignificant. It was concluded that the Herbst appliance not restricted forward growth of the maxilla. There was greater restriction of movement of the upper incisors in the treated than in the control group. The displacement of the mandible in the treated group was not higher than in the control group.


Subject(s)
Humans , Child , Orthodontic Appliances/adverse effects , Bone Remodeling , Imaging, Three-Dimensional , Malocclusion, Angle Class II , Tooth Avulsion , Cone-Beam Computed Tomography
12.
Braz. dent. j ; 25(3): 179-185, 07/2014. tab, graf
Article in English | LILACS | ID: lil-722153

ABSTRACT

Immunoexpression of PPAR-γ and osteocalcin proteins was evaluated for bone repair of critical-size defects (CSDs), created in rat calvaria (n=42) and treated with fragmented abdominal autogenous adipose tissue graft. Three groups (n=14) were formed: C (control - blood clot), AB (autogenous bone) and AT (fragmented adipose tissue). The groups were divided into subgroups (n=7) for euthanasia at 30 and 90 days. Histological and immunohistochemical analyses were performed. Data were subjected to descriptive statistics (mode). A complete bone closure was observed in Group AB 90 days after surgery. In Group C, repair was achieved by the formation of collagen fiber bundles oriented parallel to the wound surface at both post-surgery periods. In Group AT the type of healing was characterized by dense connective tissue containing collagen fiber bundles arranged amidst the remaining adipose tissue, with rare heterotopic bone formation associated with fibrosis and different types of tissue necrosis. Immunostaining of PPAR-γ was not observed in any specimen from Groups C and AB. In Group AT, the immunostaining of PPAR-γ was more evident 30 days after surgery. Immunostaining of osteocalcin was present in all groups and at both postoperative periods. The fragmented autogenous abdominal adipose tissue graft did not favor the repair of critical-size bone defects created surgically in rat calvaria as evidenced by the positive immunostaining of PPAR-γ protein and the negative immunostaining of osteocalcin in the osteoblast-like cells and bone matrix.


A imunoexpressão das proteínas PPAR-γ e osteocalcina foi avaliada para o reparo ósseo de defeitos de tamanho crítico (DTC) criados em calvária de ratos (n = 42) e tratados com enxerto de tecido adiposo autógeno abdominal macerado. Foram formados três grupos (n=14): C (controlo - coágulo de sangue), AB (osso autógeno) e AT (tecido adiposo fragmentado). Estes grupos foram divididos em subgrupos (n = 7) para a eutanásia em 30 e 90 dias. Foram realizadas análises histológicas e imuno-histoquímico. Os dados foram submetidos à análise estatística descritiva (moda). Um fechamento ósseo completo foi observada no grupo AB 90 dias após a cirurgia. No grupo C a reparação foi alcançada através da formação de feixes de fibras de colágeno orientadas paralelamente à superfície da ferida nos dois períodos pós-operatórios. No Grupo AT, o tipo de cicatrização predominante foi caracterizada pela presença de tecido conjuntivo denso contendo feixes de colágeno de fibras dispostas em meio ao tecido adiposo restante, com raras formações ósseas heterotópicas associada à fibrose e diferentes tipos de necrose tecidual. A imunomarcação do PPAR- γ não foi observada em nenhum espécime dos grupos C e AB. No grupo AT a imunomarcação do PPAR-γ foi mais evidente aos 30 dias de pós-operátorio. A imunomarcação da osteocalcina estava presente em todos os grupos e nos dois períodos de pós-operatório O enxerto autógeno abdominal fragmentado tecido adiposo não favoreceu a reparação de defeitos ósseos de tamanho crítico criados cirurgicamente em calvária de ratos como evidenciado pela imunomarcação positiva da proteína PPAR-γ e a imunomarcação negativa de osteocalcina nos osteoblastos e matriz óssea.


Subject(s)
Animals , Male , Rats , Abdominal Fat/transplantation , Bone and Bones/abnormalities , Osteocalcin/metabolism , PPAR gamma/metabolism , Rats, Wistar
13.
Ortho Sci., Orthod. sci. pract ; 7(27): 290-293, 2014. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-730065

ABSTRACT

O objetivo do presente estudo foi avaliar a resistência de união de bráquetes ortodônticos sobre resina composta após diferentes tratamentos de superfície. Foram confeccionados 60 discos de resina composta (Z100), fixados em cilindros de PVC com resina acrílica e distribuídos aleatoriamente em 6 grupo (n=10) de acordo com o tipo de tratamento de superfície: sem tratamento, sistema Transbond XT (adesivo e resina) (Grupo 1- controle); ácido fosfórico 37% + sistema Transbond XT (Grupo 2); jateamento com óxido de alumínio + sistema Transbond XT (Grupo 3); adesivo Assure (Grupo 4); ácido fosfórico 37% + adesivo Assure e resina Transbond XT (Grupo 5) e jateamento com óxido de alumínio + adesivo Assure e resina Transbond XT (Grupo 6). Todos foram submetidos ao ensaio de resistência ao cisalhamento em uma máquina de ensaio mecânico (Emic DL 2000) a uma velocidade de 0,5 mm/min. Os dados obtidos foram submetidos à análise de variância a dois critérios ANOVA. Os dados não apresentaram diferença entre os grupos avaliados. Conclui-se que sobre a resina Z100 os bráquetes metálicos podem ser colados com sistema Transbond XT ou utilizando o adesivo Assure de forma clinicamente aceitável. O tratamento sobre a resina com ácido fosfórico ou jateamento com óxido de alumínio não favoreceram a adesão.


The aim of this study was to evaluate the bond strength of orthodontic brackets on composite resin after different surface treatments. Sixty composite resin discs (Z100) were fabricated and divided into 6 groups (n = 10) according to different surface treatments: no treatment Transbond XT system (adhesive and resin) (Group 1-control); 37% phosphoric acid gel + Transbond XT system (Group 2); sandblasting with aluminum oxide + Transbond XT system (Group 3); Assure + Transbond XT resin (Group 4); 37% phosphoric acid + adhesive Assure + Transbond XT resin (Group 5); sandblasting with aluminum-oxide + Assure + Transbond XT resin (Group 6). Brackets were fixed with Transbond XT and shear bond strength was tested in a universal testing machine (EMIC DL 2000) at 0.5 mm/min speed. Data were submitted to ANOVA and no significant difference was observed among the groups. It was concluded that when applied on Z100 resin surface metallic brackets bonded using Transbond XT system or Assure have clinic acceptable results. Resin surface treatment with phosphoric acid or sandblasting with aluminum oxide did not favor adhesion.


Subject(s)
Orthodontic Brackets , Orthodontics , Shear Strength
14.
Ortho Sci., Orthod. sci. pract ; 7(27): 272-278, 2014. ilus
Article in English | LILACS, BBO | ID: lil-730067

ABSTRACT

As quebras do aparelho de Herbst que podem surgir durante o tratamento da má oclusão de Classe II são preocupantes. Da mesma forma que as quebras com os aparelhos fixos geram compromissos adicionais para os pacientes, além do desconforto associado, incluindo também perda de horas de trabalho e tempo. Isso tudo gera custos financeiros adicionais para o consultório e/ou para o paciente e seus responsáveis. A literatura tem mostrado que, independente do desenho do aparelho utlizado, as chances de surgirem complicações durante a utilização do aparelho de Herbst são grandes. Entretanto, isso não deveria desestimular o clínico a utilizar esse tipo de aparelho, pois ele é o aparelho mais eficiente para a correção da Classe com retrognatismo mandibular. O objetivo deste artigo é descrever as principais complicações clínicas observadas com dois tipos de aparelho de Herbst, com cantilever e com splint removível inferior, e sugerir as possíveis soluções para cada situação. As complicações foram classificadas de acordo com o grau de complexidade, em simples e complexas. Após a descrição das complicações e das suas soluções, concluiu-se que é comum a ocorrência de alguma complicação durante o tratamento com o aparelho de Herbst. Sendo assim, o clínico deve estar apto a resolvê-la. Para diminuir as complicações, o aparelho deve ser construído com coroas de aço usando um sistema telescópico sem parafusos. Do ponto de vista clínico, o aparelho de Herbst com cantilever apresenta mais vantagens do que com o splint removível inferior durante a correção da Classe II


The breakages of the Herbst appliance that may arise during the treatment of Class II malocclusion are worrying. Like it happens with breakages of fixed appliances it generates additional appointments; on the loss of work hours and time. Such consequences generate higher costs for the office and/or for the family of the patient. The literature has shown that there are great chances of complications during the use of the Herbst appliance. However, this should not discourage the clinician to use this type of appliance since it is the most efficient on the correction of Class II with mandibular retrognathia. The purpose of this article was to describe the main clinical complications observed on two types of Herbst appliance, with cantilever and with lower removable splint, and suggest possible solutions for each situation. Complications were classified according to the degree of complexity in simple and complex. After a description of the complications and their solutions, it was concluded that it is common the occurrence of complications during the treatment with Herbst appliance. Thus, the clinician should be able to solve them. To minimize these complications, the appliance should be constructed with steel crowns and with a telescopic system without screws. From a clinical standpoint, the Herbst appliance with cantilever presents more advantages than the lower removable splint for the correction of Class II.


Subject(s)
Humans , Malocclusion, Angle Class II , Orthodontics
15.
RSBO (Impr.) ; 10(1): 9-9, Jan.-Mar. 2013.
Article in English | LILACS | ID: lil-695905
16.
Ortho Sci., Orthod. sci. pract ; 6(22): 170-177, 2013. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-729324

ABSTRACT

O principal objetivo da ERM (Expansão Rápida da Maxila) é a separação ortopédica da sutura palatina mediana para correção da deficiência maxilar transversal. Para diminuir os efeitos dentários e aumentar os efeitos ortopédicos tem sido sugerida a associação da ERM com a ancoragem esquelética. O objetivo deste estudo foi avaliar as principais intercorrências relacionadas com a ERM utilizando um disjuntor de Haas ancorado com mini-parafusos em 14 pacientes com idade média de 16,5 anos, considerando sinais e sintomas associados, alterações relacionadas aos mini-parafusos, alterações dentárias, alterações oclusais e articular e o grau de desconforto geral. Os resultados obtidos foram apresentados considerando-se frequências e percentuais. Para a comparação do desconforto geral (Escala de Análise Visual) entre os momentos avaliados foi considerado o teste não paramétrico de Wilcoxon, levando-se em conta a correção de Bonferroni (p<0,05). Não foram relatados ou observados sinais e sintomas clinicamente significantes. Também não foram observadas intercorrências relevantes clinicamente em relação aos mini-parafusos. As alterações dentárias observadas estiveram dentro dos resultados esperados, considerando o procedimento da ERM convencional, e também não foram observadas alterações oclusais e articulares clinicamente significantes. A avaliação da Escala de Análise Visual mostrou que o desconforto geral relatado variou de 3.1 à 4, sem diferença estatística entre os momentos estudados. A ERM por meio do disjuntor de Haas associado à mini-parafusos mostrou-se segura e confiável, sem apresentar intercorrências que contraindiquem seu uso.


The main objective of RME is the orthopedic separation of the median palatine suture to correct transversal maxillary deficiency. To reduce dental effects and to increase orthopedic effects the association between RME and skeletal anchorage has been suggested. The purpose of this study was to evaluate the main complications related to RME using a Haas disjunctor anchored with mini-screws in 14 patients, average age of 16.5 years old, considering signs and symptoms associated, changes related to the mini-screws, dental changes, occlusion and articular changes and general discomfort degree. Results were presented considering frequency and percentage. To compare general discomfort (Visual Analysis Scale) among moments the non-parametric Wilcoxon test was used, considering Bonferroni correction (p<0.05). No signs or symptoms were reported or observed as clinically significant. No clinically relevant complications about the mini-screws were observed. Dental changes were within the expected results, considering conventional RME procedure and no occlusal or articular clinically significant changes were observed. Considering the Visual Analysis Scale the general discomfort related varied from 3.1 to 4, with no statistical difference among the moments studied. RME using Haas disjunctor associated to mini-screws has proved to be a safe and reliable procedure without side effects that could contraindicate its use.


Subject(s)
Humans , Orthodontic Anchorage Procedures , Orthodontics , Palatal Expansion Technique
17.
Ortho Sci., Orthod. sci. pract ; 6(23): 291-299, 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-707583

ABSTRACT

O objetivo desse trabalho foi verificar as possíveis variações nas distâncias interdentárias entre caninos, primeiros pré-molares e primeiros molares superiores em modelos de gesso e em tomografias computadorizadas de feixe cônico (TCFC) antes e após a expansão rápida da maxila (ERM) com ancoragem esquelética, correlacionando essas medidas com a abertura da sutura palatina mediana. A amostra consistiu de 13 pacientes com idade média de 16 anos que se submeteram à ERM com um aparelho do tipo Haas ancorado no palato com parafusos de titânio. Para a comparação entre os momentos de avaliação (inicial e final) e entre os métodos (modelos de gesso e TCFC) foi utilizado o teste t de Student para amostras pareadas (p<0,05). Para avaliar a associação entre as variáveis foi estimado o coeficiente de correlação de Pearson. Na comparação entre os momentos estudados houve diferença estatística significante em todas as distâncias interdentárias avaliadas nos dois métodos utilizados, bem como na abertura da sutura. Na comparação entre os métodos não houve diferença estatística significante. Também não houve correlação entre a diferença das distâncias interdentárias e a abertura da sutura. Concluiu-se que houve um aumento significante na largura do arco dentário superior, mas que não correspondeu a um aumento proporcional da abertura da sutura palatina mediana aos níveis dos elementos dentários analisados.


The purpose of this study was to verify possible differences of interdental distances between upper canines, first premolars and first molars in plaster casts and in cone-beam computed tomography (CBCT) before and after rapid maxillary expansion (RME) with skeletal anchorage and correlating these distances with the opening of midpalatal suture. The sample was composed of 13 patients, mean age of 16 years old, that were submitted to RME with Haas appliance anchored to the palatal plate with titanium screws. To compare the stages of evaluation (beginning and ending) and the methods (plaster casts and CBCT) Student t test for paired samples was used (p<0.05). To evaluate the association among measurements Pearson´s correlation was estimated. When comparing moments of measurements, there was significant statistical difference in all interdental distances evaluated in both methods as well as in the suture opening. There was no statistical difference in the comparison of both methods. There was no correlation between interdental differences and suture opening either. It was concluded that there was a significant increase in the width of the maxillary dental arch that however did not correspond to a proportional augmentation of the opening of midpalatal suture at the level of the studied dental elements.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Orthodontic Anchorage Procedures , Palatal Expansion Technique
18.
Ortho Sci., Orthod. sci. pract ; 6(23): 338-345, 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-707587

ABSTRACT

Avaliações das alterações esqueléticas em pacientes tratados com o aparelho de Herbst já foram amplamente descritas por meio de comparações em telerradiografias laterais, porém há pouca análise dessas alterações em tomografias tridimensionais. O objetivo do estudo foi avaliar as alterações esqueléticas e dentoalveolares de um paciente com má oclusão de Classe II, 1ª divisão, tratado com aparelho de Herbst (idade inicial de 10,6 anos e final de 11,6 anos) por meio da sobreposição de modelos tridimensionais utilizando tomografia computadorizada de feixe cônico (TCFC). Foram realizadas tomografias antes (T0), após 6 meses de tratamento (T1) e ao final de um ano de tratamento (T2). Modelos 3D foram construídos e sobrepostos utilizando a base do crânio de T0 como referência. Os deslocamentos (T0-T1; T1-T2; T0-T2) das regiões anatômicas de interesse (incisivos superiores e inferiores, anterior de maxila, anterior e inferior de mandíbula, mento, borda posterior da mandíbula, côndilo e fossa articular) foram visualizados e quantificados utilizando mapas coloridos tridimensionais. Os deslocamentos das regiões anatômicas avaliadas indicaram que as adaptações esqueléticas e dentárias após 1 ano de tratamento com o aparelho de Herbst favoreceram a correção da má oclusão de Classe II.


The aim of this study was to evaluate skeletal and dental changes in a patient with Class II division 1 malocclusion treated with Herbst appliance (initial age 10.6 years, final age 11.6 years) by superimposing three-dimensional cone beam computed tomography (CBCT). CBCT scans were performed before (T0), after 6 months of treatment (T1), and after 1 year of treatment (T2). 3D models were constructed and superimposed, using the cranial base of T0 as a reference. Displacement (T0-T1; T1-T2; T0-T2) of the anatomical regions of interest (upper and lower incisors, anterior maxilla, anterior and lower mandible, chin, rami, condyle and glenoid fossa) were visualized and quantified (in mm) using color maps. It was concluded that the displacement of the anatomic regions indicated that the skeletal and dental changes after 1 year of treatment with Herbst appliance favored the correction of Class II malocclusion.


Subject(s)
Humans , Male , Child , Imaging, Three-Dimensional , Malocclusion, Angle Class II , Tomography
19.
Ortho Sci., Orthod. sci. pract ; 6(21): 33-40, 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-681602

ABSTRACT

O objetivo deste estudo piloto foi avaliar a perda óssea na região dos incisivos inferiores, bem como a inclinação e a protrusão incisal inferior após o uso do aparelho de Herbst para o tratamento da Classe II. Foram selecionados 10 pacientes do grupo controle (G1) com idade média, inicial e final, de 8,9 a 10,4 anos, acompanhados por um período de 18 meses sem o uso do aparelho. E para o grupo tratado (G2) foram selecionados 6 pacientes, com idade média, inicial e final, de 10,8 a 11,4 anos, tratados com aparelho de Herbst com cantilever por um período de 6 meses. Para cada grupo foram realizados dois exames de tomografia computadorizada de feixe cônico (TCFC), T1 inicial e T2 final. Nas TCFC foram avaliadas, na região dos incisivos inferiores, a espessura do osso medular, a espessura das corticais vestibular e lingual, e a protrusão e a inclinação dos incisivos inferiores, utilizando o software InVivo 5.0. Os dados foram submetidos à análise estatística (análise de covariância e test t) com nível de significância de 5%. Como resultado, observou-se que a cortical vestibular na região entre os dentes 41 e 42 mostrou um aumento significativo no grupo controle (0,30 mm). A espessura da cortical lingual mostrou uma alteração significativa apenas no grupo controle na região entre os dentes 32 e 31 (0,46 mm). Para a medição da protrusão do incisivo inferior, houve uma diminuição dos valores, que foi significativa apenas para o grupo controle (-0,79 mm). Pode-se concluir que o aparelho de Herbst com cantilever não provocou perda óssea nas corticais vestibular e lingual. Durante os 6 meses iniciais de utilização do aparelho houve uma pequena vestibularização e protrusão anterior dos incisivos inferiores, sem implicações clínicas relevantes.


The aim of this pilot study was to evaluate bone loss in the region of the lower incisors and the incisal inclination and protrusion after Class II treatment with Herbst appliance.10 patients from the control group (G1)with initial and final mean ages of 8.9 to 10.4 years were selected and followed by a period of 18 months with out the use of the device. For the treated group (G2), 6 patients with initial and final mean ages of 10.8 to 11.4 years were treated with Herbst appliance with cantilever for a period of 6 months. Two cone beam computed tomography (CBCT) exams were carried out for each group, before treatment (T1- initial) and after 6 months (T2 - final). Through CBCT images from the region of the lower incisors, were evaluated the thickness of the bone marrow, the thickness of vestibular and lingual cortical, and protrusion and inclination of lower incisors, using the software In Vivo 5.0. Data were submitted to statistical analysis (analysis of covariance and T test) with a significance level of 5%. As a result it was observed that the cortical bone in the region between the teeth 41and 42 showed a significant in crease on the control group patients (0.30 mm). The thickness of the lingual cortical presented a significant change only in the control group on the are a between teeth 32 and 31 (0.46 mm). Regarding the protrusi on of the lower incisors, there was a decrease of values which was significant only for the control group (-0.79 mm). It can be concluded that the Herbst appliance with cantilever does not cause bone lossin vestibular and lingual cortical. During the initial 6 months of treatment, there was a small vestibular inclination and anterior protrusion of the lower incisors with out relevant clinical implications.


Subject(s)
Humans , Child , Alveolar Bone Loss , Malocclusion , Malocclusion, Angle Class II
20.
Braz. j. oral sci ; 11(4): 458-462, Oct.-Dec. 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-668672

ABSTRACT

Aim: To evaluate the bond strength of brackets fixed with different materials (two light-cured nanofilled resins - Transbond Supreme LV and Flow Tain LV, a light-cured resin - Transbond XT(control) and two chemically cured resins for indirect bonding - Sondhi Rapid- Set and Custom I.Q.) using the indirect bonding technique after 10 min and 24 h, and evaluate the type of failure. Methods: One hundred premolars were selected and randomly divided into groups (n=10) according to the material and fixation period. The brackets were bonded through the indirect technique following the manufacturer’s instructions and stored in deionized water at 37oC for 10 min or 24 h. After, the specimens were submitted to a shear bond strength (SBS) test (Instron) at 0.5 mm/min and evaluated for adhesive remnant index (ARI). The data were submitted to ANOVA and Tukey’s test (p<0.05) and the ARI scores were submitted to the chi-square test. Results: It could be observed a significant difference among the materials (Flow Tain LV = TransbondSupreme LV = Transbond XT> Sondhi Rapid-Set > Custom I.Q.). There was no significant difference in resistance values between 10 min and 24 h, regardless of the materials. Most groups showed adhesive remaining adhered to the enamel (scores 2 and 3) without statistically significant difference (p>0.05). Conclusions: It was concluded that the light-cured nanofilled materials used in indirect bonding showed greater resistance than the chemically cured materials. The period of fixation had no influence on the resistance for different materials.


Subject(s)
Orthodontic Brackets , Orthodontics/methods
SELECTION OF CITATIONS
SEARCH DETAIL